The Replacement Policy Products (i.e. cylinders, impacts, and others) manufactured by Catalina Cylinders and Catalina East Division will be replaced at no cost to the customer if, after evaluation of the product at the appropriate manufacturing facility, the product...
The requalification of cylinders was formally known as the retesting of cylinders. Requalification is done to ensure that a cylinder is still acceptable to continue to be used as a pressure vessel to transport hazardous material. DOT requalifying of a cylinder and the...
Catalina Cylinders recommends that paint be removed from aluminum cylinders by the use of gel-type (non-caustic) paint strippers instead of sanding, abrasive blasting, or any methods of exposure to heat. Removal of paint from a cylinder by sanding or abrasive blasting...
Aluminum cylinders should not be exposed to elevated temperatures, 350°F (176°C) or greater, or the action of fire for any period of time. In section (f) (4) of 49 CFR part 173.34, DOT-3AL and DOT-4E, aluminum cylinders subjected to fire must be removed from service....
All DOT 3AL / TC-3ALM 6061 aluminum cylinders manufactured by Catalina Cylinders and Catalina East Division are non-magnetic. This includes all DOT-3AL /TC-3ALM medical oxygen cylinders. Please consult the appropriate cylinder accessory manufacturer for the magnetic...